cRIO PBMS configuration (Master/Slave) in cRIO 9055 / 9057 / 9058
Issue:
During the PROFIBUS configuration with the Configurator 3 an issue occurs which doesn't allow to configure the cRIO PBMS.
The cRIO PBMS used in the latest cRIO Controllers/Chassis (9055 / 9057 / 9058) need to be configured as described below.
The hardware doesn't show up in the Configurator 3 Hardware Selection |
Sources:
Download and extract the files |
|
Copy the bitfiles to your PC:
| “C:\Program Files (x86)\KUNBUS GmbH\Configurator III\BitFiles\” |
Solution:
Iit is now possible to configure KUNBUS modules for cRIO-9055 with Configurator III with the following workaround.
Please install the PBMS package incl. Configurator III from VI Package Manager if not done yet
Download the attatched CS_LV_VISA.DLL file
rename the original CS_LV_VISA.DLL to back it up.
copy the downloaded DLL file to
C:\Program Files (x86)\Kunbus GmbH\Configurator III\
While the modified CS_LV_VISA.DLL is added, the online/monitor mode of Configurator III will not work even with previous cRIO Chassis.
If you would work with cRIO Chassis published pre LabVIEW 2019 using the online/monitor mode, please rename the original DLL file to CS_LV_VISA.DLL.
Download the attatched bitfile
CSLVVISA_cRIO-9055[4].lbvitx
copy it to
C:\Program Files (x86)\KUNBUS GmbH\Configurator III\BitFiles\
Start Configurator III.
Please note due to changes at the NI´s FPGA-API it is currently not possible to use the online/monitor mode of Configurator III. However, the download process will complete successfuly and the diagnose messages might be read out by executing our Getting Started example.