cRIO PBMS configuration (Master/Slave) in cRIO 9055 / 9057 / 9058

cRIO PBMS configuration (Master/Slave) in cRIO 9055 / 9057 / 9058

Issue:

During the PROFIBUS configuration with the Configurator 3 an issue occurs which doesn't allow to configure the cRIO PBMS.

The cRIO PBMS used in the latest cRIO Controllers/Chassis (9055 / 9057 / 9058) need to be configured as described below.

The hardware doesn't show up in the Configurator 3 Hardware Selection

Sources:

Download and extract the files

 

Copy the bitfiles to your PC:

 

“C:\Program Files (x86)\KUNBUS GmbH\Configurator III\BitFiles\”

Solution:

Iit is now possible to configure KUNBUS modules for cRIO-9055 with Configurator III with the following workaround.

  1. Please install the PBMS package incl. Configurator III from VI Package Manager if not done yet

  2. Download the attatched CS_LV_VISA.DLL file

    1. rename the original CS_LV_VISA.DLL to back it up.

    2. copy the downloaded DLL file to C:\Program Files (x86)\Kunbus GmbH\Configurator III\

    3. While the modified CS_LV_VISA.DLL is added, the online/monitor mode of Configurator III will not work even with previous cRIO Chassis.

    4. If you would work with cRIO Chassis published pre LabVIEW 2019 using the online/monitor mode, please rename the original DLL file to CS_LV_VISA.DLL.

  3. Download the attatched bitfile CSLVVISA_cRIO-9055[4].lbvitx

    1. copy it to C:\Program Files (x86)\KUNBUS GmbH\Configurator III\BitFiles\

  4. Start Configurator III.

Please note due to changes at the NI´s FPGA-API it is currently not possible to use the online/monitor mode of Configurator III. However, the download process will complete successfuly and the diagnose messages might be read out by executing our Getting Started example.

Related content

cRIO PBMS configuration (PROFIBUS Master/Slave) in cRIO 904X / 905X
cRIO PBMS configuration (PROFIBUS Master/Slave) in cRIO 904X / 905X
More like this
cRIO Supported Hardware
cRIO Supported Hardware
More like this
Possible LabVIEW Errors in cRIO PBMS Master Example
Possible LabVIEW Errors in cRIO PBMS Master Example
More like this
Configurator III Log - Profibus Master
Configurator III Log - Profibus Master
More like this
DF PROFINET IO | configure the boards within a PXI System running NI Linux Real-Time
DF PROFINET IO | configure the boards within a PXI System running NI Linux Real-Time
More like this
DF PROFINET IO | Support Request - LabVIEW VISA DRIVER
DF PROFINET IO | Support Request - LabVIEW VISA DRIVER
More like this