Files needed
Pleasre request the required files from the KUNBUS Support team.This manual is only suitable for the following Modular Gateway modules:
Product | Article No. |
---|---|
100074 | |
100066 | |
100073 |
Preparation
You have noticed an anomaly in one of the modules listed above
Send us a photo of the front side of your module
You will receive an archive from the Customer Support
Instructions
Note |
---|
Make sure that the module is not disconnected from the power supply during the process |
...
Unpack the archive you received from the Customer Support
Assign the module a network configuration so that you can reach the module in the network
Connect to the module with
...
an FTP program, e.g. FileZilla.
User: Admin
Password: 1701
Copy the
...
firmware file into the root directory - usually a KFU file
Copy the content of the folder "targetfiles" into the root directory
Wait until all transfers have been completed successfully
Reboot
Now disconnect the device from power for at least 5 seconds
...
Switch the device on again and wait at least
...
one minute.
Check
You can check the firmware version via
Login on the web frontend