Preparation

Teltonika

Teltonika RUT-955 956 will act as a Modbus Client. The configuration of the slave is done in the web interface. The web address is 192.168.1.1.

...

  • Login

  • Select Services/Modbus in the menu

  • Activate Modbus TCP slave client as shown in the following picture. Do not forget to save.

...

QModMaster

QModMaster will act as masterModbus TCP Server.

Steps Configure QModMaster as MasterServer.

Select Modbus TCP in the Options menu and enter the parameters of the slave Client (IP address and port).

...

Info

Pay attention to the settings in the Settings of the Menu Options

...

  • Writing and reading the data

    • The function code for reading is 0x06 → "Write Single Register (0x06)

    • The function code for writing is 0x06 → "Read Holding Registers (0x03)

  • Register Address to address the open collector output to enter as Start Address.

    • The register address for the output (open collector output) is 202 (BOOL⇾ 0|1)

    • The register address for the relay output PIN is 203 (BOOL⇾ 0|1)

    • For writing, use the field number 4 3 as shown in the picture below and press Enter (don't forget!).

...

Example

...

...