Files needed

Here is the latest firmware for KIC-Profinet: 1.5.12906, SW0046R04

View file
nameSW0046R04.zip

Instructions

Note

Make sure that the module is not disconnected from the power supply during the process

  1. Set IP address e.g. with the tool PRONETA from Siemens

  2. Connect to the module with a FTP program e.g. FileZilla.

    1. User: Admin

    2. Password: 1701

  3. Copy the KFU file into the root directory

  4. Copy the content of the folder "targetfiles" into the root directory

  5. Wait until all transfers have been completed successfully

Reboot

  1. Now disconnect the device from power for at least 5 seconds

  2. Reconnect the circuit for at least 1 minute

Check

You can check the firmware version via

  • Login on the web frontend

  • Calling the CDI menu "Module Information”

  • Query of the register 0x4009