Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

This is here an article how to start up the Teltonika router, as well as ports how digital outputs can be switched.

...

This is not a KUNBUS product, so we do not provide support for it. If you have any questions, please contact the dealer/company.

What is needed?

Drawio
mVer2
zoom1
simple0
inComment0
custContentId3047752066
pageId2865234010
lbox1
diagramDisplayNameUnbenanntes Diagramm-1690471908676.drawio
contentVer4
revision4
baseUrlhttps://kunbus-gmbh.atlassian.net/wiki
diagramNameUnbenanntes Diagramm-1690471908676.drawio
pCenter0
width1002.48
links
tbstyle
height270

Teltonika

...

Preparation

Teltonika

Teltonika RUT-956 will act as a slaveModbus Client. The configuration of the slave is done in the web interface. The web address is 192.168.1.1.

Steps of the configuration Teltonika

  • Login (with BN and PW)

  • Select Services/Modbus in the menu

  • Activate Modbus TCP slave client as shown in the following picture. Do not forget to save.

...

...

QModMaster

Qmodmaster QModMaster will act as masterModbus TCP Server.

Steps Configure Qmodmaster QModMaster as MasterServer.

Select Modbus TCP in the Options menu and enter the parameters of the slave Client (IP address and port).

...

Info

Pay attention to the settings in the Settings of the Menu Options

...

  • Writing and reading the data

    • The function code for reading is 0x06 → "Write Single Register (0x06)

    • The function code for writing is 0x06 → "Read Holding Registers (0x03)

  • Register Address to address the open collector output to enter as Start Address.

    • The register address for the output (open collector output) is 202 (BOOL⇾ 0|1)

    • The register address for the relay output PIN is 203 (BOOL⇾ 0|1)

    • For writing, use the field number 4 3 as shown in the picture below and press Enter (don't forget!).

...

...

Example

...