The digital outputs of the RevPi Compact Module cause a peak when switching on, what can I do?

Yes, this is unfortunately a known issue. We are currently working on this bug. Unfortunately, we can't influence the behaviour. The output pins on the Compact come directly from the compute module, and we have no influence on this behaviour at boot time.

...

What was the solution?

What is the XXX chip used to multiplex analogue to digital conversions (item 2)?

...

  • The multiplexer: DG408LE

  • the selection of the analog input is done via GPIO6, GPIO12 and GPIO13

GPIO

DG408LE

GPIO6

A0

GPIO12

A1

GPIO13

A2

How can I access the Digital Inputs / Outputs from Codesys?

...

No, the range is 0 - 10 V.

8 x analog Inputs
0-10 V DC, single ended, 16 Bit at piControl, 21 Bit raw value, software switchable current source 2.5 mA

2 x analog Outputs
0-10 V, short-circuit proof, protection against backfeeding, 8-bit resolution,
1 % accuracy, max. current load 10 mA (10 V DC @ 1 k)

https://revolution.kunbus.com/revpi-compact/

...