Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

This is not a KUNBUS product, so we do not provide support for it. If you have any questions, please contact the dealer/company.

What is needed?

Drawio
custContentId287.68000000000006
mVer2
simple0
zoom1simple0
inComment0
3047752066pageId2865234010
lboxcustContentId13047752066
diagramDisplayNameUnbenanntes Diagramm-1690471908676.drawio
lbox1
contentVer24
revision24
baseUrlhttps://kunbus-gmbh.atlassian.net/wiki
diagramNameUnbenanntes Diagramm-1690471908676.drawio
pCenter0
width9581002.48
links
tbstyle
height270

Preparation

Teltonika

Teltonika RUT-955 956 will act as a Modbus Client. The configuration of the slave is done in the web interface. The web address is 192.168.1.1.

...

  • Login

  • Select Services/Modbus in the menu

  • Activate Modbus TCP slave client as shown in the following picture. Do not forget to save.

...

QModMaster

QModMaster will act as masterModbus TCP Server.

Steps Configure QModMaster as MasterServer.

Select Modbus TCP in the Options menu and enter the parameters of the slave Client (IP address and port).

...

Info

Pay attention to the settings in the Settings of the Menu Options

...

  • Writing and reading the data

    • The function code for reading is 0x06 → "Write Single Register (0x06)

    • The function code for writing is 0x06 → "Read Holding Registers (0x03)

  • Register Address to address the open collector output to enter as Start Address.

    • The register address for the output (open collector output) is 202 (BOOL⇾ 0|1)

    • The register address for the relay output PIN is 203 (BOOL⇾ 0|1)

    • For writing, use the field number 4 as shown in the picture below and press Enter (don't forget!).

...

...